Cebora Synstar 350TS - Pulse, Double Pulse

Price unknown
Verified by RWTPartner

Description

Аппарат создан для производственных нужд. Надежный промышленный вариант и лаконичное исполнение силовой части. Имеет встроенный блок водяного охлаждения, оцинкованный стальной корпус, 100% ПВ на максимальном токе 300А при температуре 40C. Идеально справляется со сваркой: черной стали, нержавеющей стали марок 304, 308, 316, сплавов алюминия! Имеет функции Pulse, Double Pulse!

Set information

Manufacturer
Cebora
Family
Synstar 350 TS
Source
Synstar 350 TS
Earth cable
25мм2*5
Torch/gun
Kemppi GX 303G
Wire feeder
Synstar 350 TS
Welding processes
111, 135, 136

Technical specifications

Phase
3
Gouging
No
Supply voltage min.
304
Supply voltage max.
437

Welding method 111

Current and voltage

Minimum current
10 A
Maximum current
350 A

Data for 40°C duty cycle

PercentCurrent (A)Voltage (V)
1003000
603200
403400

Inductance

Minimum inductance adjustment
0%
Maximum inductance adjustment
100%

Current and polarity

Current and polarity
DC-, DC+

Start adjustment (hot/cold start)

Ignition current
No adjustment
Hot/cold start current
0%-100%
Hot/cold start time
0.00s-1.00s

Welding method 135

Current and voltage

Minimum current
10
Maximum current
340
Minimum voltage
10.0
Maximum voltage
40.0

Wire feed

Minimum wire feed speed
0.7
Maximum wire feed speed
22.0
Manual mode
Yes

Synergetics

Number of programs
30

Data for 40°C duty cycle

PercentCurrent (A)Voltage (V)
1003000
603200
403400

Inductance

Minimum inductance adjustment
- 9.9
Maximum inductance adjustment
9.9

Current and polarity

Current and polarity
DC+

Start adjustment (hot/cold start)

Ignition current
No adjustment
Hot/cold start current
10%-200%
Hot/cold start time
0.1s-10.0s

Crater filling (arc extinction)

Search arc
No adjustment
Downtime
0.1s-10.0s
Crater filling current
10%-200%
Crater filling time
0.1s-10s
End current
No adjustment

Pulse

Minimum pulse frequency
Not regulated
Maximum pulse frequency
Not regulated
Maximum pulse current
350 A
Minimum pulse current
20 A
Pulse duty cycle
Not regulated

Double pulse

Upper pulse frequency
Not regulated
Average current of upper pulse
Not regulated
Maximum current of upper pulse
350 A
Minimum current of upper pulse
20 A
Duty cycle of upper pulse
Not regulated
Lower pulse frequency
0.1 Hz - 5.0Hz
Average current of lower pulse
Not regulated
Maximum current of lower pulse
3.0 m/min
Minimum current of lower pulse
0.1 m/min
Duty cycle of lower pulse
Not regulated
Average current of double pulse
Not regulated
Duty cycle between upper and lower pulses
25%-75%

Additional

Additional features
1) Start Mode 2) Spot 3) Soft Taime 4) Burdbank Correction 5) Predgas 6) Postgas 7) Каналы памяти 8) Test gas 9) Протяжка проволоки
Description
1) 2T; 4T; 3L 2) Spot Timi (0.3s - 25.0s); Pause Timi (0.0s - 5.0s) 3) 1% - 100% 4) (-125+125) 5) 0.0s - 10.0s 6) 0.0s - 25.0s 7) 99 8) 30s 9) 10,0 m/min

Welding method 135

Current and voltage

Minimum current
10
Maximum current
340
Minimum voltage
10
Maximum voltage
40

Wire feed

Minimum wire feed speed
0,7
Maximum wire feed speed
22,0
Manual mode
No

Data for 40°C duty cycle

PercentCurrent (A)Voltage (V)
1003000
603200
403400

Inductance

Minimum inductance adjustment
No data
Maximum inductance adjustment
No data

Pulse

Minimum pulse frequency
No data
Maximum pulse frequency
No data
Maximum pulse current
No data